1. AsingleASF-75GorASF-60Gauto-liftgasfryer
requires a minimum of 120 CFM make-up air for
naturalgasand48CFMforpropanegas.Kitchen
ventilation must be of sufficient capacity to prevent
a negative-pressure condition. DO NOT obstruct or
restrict ventilation nor the air flow required to support
combustion.
2. DO NOTobstructtheflowoftheexhaustflueatthe
top rear of the fryer. It is especially critical that gas
supply piping and electrical support cord and/or
receptacle be routed away from the path of the hot
combustion fumes.
3. This fryer cannot be direct vented.
4. Install the fryer under a ventilation hood meeting all
applicable code requirements. Combustion fumes
must be vented in accordance with local, state, or
national codes.
VENTILATION
An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing
totheNationalFireProtectionAssociation,BatterymarchPark,Quincy,MA02269.WhenwritingrefertoNFPANo.96.
DANGER
Installation, air adjustment and/or
service work must be in accordance
with all local codes and must be
performed by a certifi ed service
technician qualifi ed to work on
gas appliances.
CAUTION
To prevent malfunction or cause
negative back draft, DO NOT obstruct
exhaust fl ues or attach any fl ue
extension that will impede proper
burner operation.
INSTALLATION
Gas Fryer Operation & Care Manual 7
DANGER
FAILURE TO VENT THIS FRYER PROPERLY
MAY BE HAZARDOUS TO THE
HEALTH OF THE OPERATOR.
Equipment damage and operational problems
may also be the consequence of improper venting.
Any damages sustained by a failure to properly vent
this fryer are not covered under warranty.
Ventilatinghoodsandexhaustsystemsshallbepermittedtobe
used to vent appliances installed in commercial applications.
Whereautomaticallyoperatedappliancesareventedthrougha
ventilatinghoodorexhaustsystemequippedwithadamperor
withapowermeansofexhaust,provisionsshallbemadetoallow
theflowofgastothemainburnersonlywhenthedamperisopen
to a position to properly vent the appliance and when the power
meansofexhaustisinoperation.
in accordance with nfpa 54
commonwealth of massachusetts only.
WARNING
This appliance shall be installed in
conformity with the current regulations
and used only in a well ventilated location.
Consult the instructions before
installing and using this appliance.