COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 8.
COMBITHERM® PRE-INSTALLATION CHECKLIST CONTINUED
DRAIN:
Is there a proper  oor drain within 6' (1829mm) of the oven?

Actual distance to  oor drain:
Using the diagram provided,
mark the location of the drain.
Draw a simple detail on how the
oven’s drain line will be routed
to the  oor drain.
Be sure to use best practices
when routing the line to keep it
as short as possible.
The drain line should have a
positive descending slope. Verify
1/8" (3.2mm) pitch to 10' (305cm)
of drain line.
COMMENTS:
Bottom 5-1/8" (130mm)
Top 20" (508mm)
Back 4" (102mm)
Right side 0" (0mm) from non-combustible materials
Left side 0" (0mm)
Recommended 18" (457mm) for service access
2" (51mm) from combustible materials
6' (1829mm)
6' (1829mm)
6' (1829mm)