The filters are the only owner-serviceable components of the
ventilator hood system. For all problems which cannot be
remedied by servicing the filters, contact an authorized service
agency for Fryer or Ventilator or an authorized Ansul
distributor for the fire suppression system.
PROBLEM REMEDY
Unit will not operate. Circuit breaker is tripped.
Reset breaker. If tripping persists,
contact a licensed electrician for
repair of field wiring or contact an
authorized service agency for
repairs.
A buzzer sounds Ansul
®
system has tripped. Contact
continuously and unit an authorized Ansul
®
agent for
will not operate. service and repairs.
Check Filters light is lit. HEPA filter missing or not in
position. Make sure both the HEPA
filter and grease baffle are properly
installed in their respective rails.
Replace Filters light is lit. HEPA filter or charcoal filter
nearing the end of their service life.
Be sure to have proper replacement
filters on hand. Replace the HEPA
filter and charcoal filter at the same
time.
Service Required light is lit.
– HEPA filter or charcoal filter is
plugged. Replace filters.
– Fire damper on exhaust color has
closed. Contact authorized service
agency for repairs.
– One or more vacuum sensing
line(s) plugged. Contact an
authorized service agency for
repairs.
NOTE: If, after 10 seconds, there is not sufficient air flow for
proper operation, the service required light will turn ON
and the fryer will be de-energized. The power switch
must be turned OFF to reset the system before the fryer
can be operated.
IMPORTANT
Use only a factory authorized service parts and replacement
filters. Contact the Alto-Shaam factory for advice.
Normal
Maintenance Items
Charcoal Filter
HEPA Air Filter
Grease Baffle
Leg Assembly
IMPORTANT
Parts used for the Ansul
®
fire suppression system are not
serviceable by the owner/operator. Procedures for servicing fire
suppression equipment are described in Ansul
®
R-102 System
Design, Installation, Recharge and Maintenance Manual
(#418087). This manual is intended for use by authorized service
personnel only.
HAVE THIS INFORMATION AVAILABLE
IF CALLING FOR SERVICE
Operation and Care Manual #8452/53/55 • 8
TROUBLESHOOTING
SERVICE PARTS LIST
CUSTOMER SERVICE DATA
Business:__________________ Location: ______________
Installation Date:______________ Technician:_____________
Service Company:____________________________________
Address:____________________________________
___________________________________________
Phone No.:__________________________________
Equipment Model No.:_________________________________
Equipment Serial No.:_________________________________
Voltage: 208V 240V 308-415V