Alto-shaam FRYTECH ASF-60G series Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Friteusen Alto-shaam FRYTECH ASF-60G series herunter. Alto-Shaam FRYTECH ASF-60G series User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 62
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
W164 N9221 Water Street P.O. Box 450 Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800• 800.558.8744
USA/CANADA
 FAX:262.251.7067•800.329.8744
U.S.A. ONLY
www.alto-shaam.com
M N - 2 8 8 5 6 0 9 / 1 0
p r i n t e d i n u . s . a .
GAS FRYER
FryTech Series
ASF-60G and
ASF-75G
Gas Fryers
with
Deluxe Control
•INSTALLATION
•OPERATION
•MAINTENANCE
ASF-60G shown with
optional automatic
basket lifts
ASF-75G shown with
optional automatic
basket lifts
Seitenansicht 0
1 2 3 4 5 6 ... 61 62

Inhaltsverzeichnis

Seite 1 - Deluxe Control

W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800• 800.558.8744USA/CANADA FAX:262.251

Seite 2

The Alto-Shaam open gas fryer has been set to operate with either natural gas or propane as indicated on the fryer identification name plate.The appli

Seite 3 - ODOR OF GAS

Use an approved gas pipe sealant at allexternalthreadedconnections, gas piping used on gas connections must avoid sharp bends that may restrict th

Seite 4 - INSTALLATION

The fryer must be supplied with a connector that complies with all state and local installation codes.Any appliance that is not furnished with a power

Seite 5

An electrical wiring diagram is located in the front access door of the fryer. The fryer must be installed by a qualiedelectrician.Thisappliance

Seite 6

Gas Fryer Operation & Care Manual • 12OPERATIONOIL/SHORTENING REQUIREMENTSTheASF-75Grequires73-pounds(33kg)ofoilorshortening in th

Seite 7

Gas Fryer Operation & Care Manual • 13OPERATIONASF-60G, 120Vignitionalarmmasterpowerswitchoilhi-limitresetopenclosedkettle drainselectorASF

Seite 8

NOTE: Perform an initial Boil-Out to clean and sanitize the fryer before operating.Carbonized deposits along with an accumulation of oil will eventu

Seite 9

Gas Fryer Operation & Care Manual • 15OPERATION8. TurntheMasterPowerSwitch(locatedbehindthefrontaccessdoor)tothe“ON” position

Seite 10 - DANGER

Gas Fryer Operation & Care Manual • 16OPERATIONNOTE: Perform an initial Boil-Out to clean and sanitize the fryer before operating. (See p

Seite 11

Gas Fryer Operation & Care Manual • 17OPERATIONCareful observation of the finished food product will help determine optimal filtering frequ

Seite 12 - WARNING

Delivery 1Unpacking 1Safety Procedures and Precautions 2InstallationInstallation Requirements 3-11Dimension Drawings, weights & capacities 3-4C

Seite 13

FILTER REPLACEMENT1. WiththeDRAIN in the “CLOSED” position, pull the trolley from the fryer and disconnect the hose from the fryer. Useoptionaltr

Seite 14 - OPERATION

Gas Fryer Operation & Care Manual • 19OPERATIONFILTER CLEANING & MAINTENANCENOTE: Make certain to use hand protection when working wi

Seite 15

Gas Fryer Operation & Care Manual • 20OPERATIONCLEANING & MAINTENANCEOIL DISCARD HOSE OPTION:Theoildiscardhoseoption(HO-27686)is

Seite 16

Gas Fryer Operation & Care Manual • 21OPERATIONSUGGESTED FRYING TIMES i t e m m i n u t e s t e m P e r a t u r e d i s P l a y 1. F

Seite 17

Gas Fryer Operation & Care Manual • 22OPERATIONSUGGESTED FRYING TIMES ITEM MINUTES TEMPERATUREEggplant  4:00 340°F(171°C)EggRolls(fr

Seite 18

Gas Fryer Operation & Care Manual • 23OPERATIONTHOROUGHLY CLEAN DAILY The cleanliness and appearance of this unit will contribute consid

Seite 19

PANEL IDENTIFICATIONDUAL CONTROL PANEL IDENTIFICATION 1. POWER O N KEY 2. POWER ON INDICATOR LIGHT 3. L.E.D. 4-DIGIT DISPLAY 4. ALPHA/NUMERIC DI

Seite 20

PROGRAMMED PRODUCT KEY OPERATION1. TURN THE POWER SWITCH LOCATED BEHIND THE LOWER FRONT ACCESS DOOR TO THE “ON” POSITION. Press the HI-LIMIT RESET

Seite 21

PROGRAMMED PRODUCT KEY OPERATION5. If shake-time has been programmed into the selected product: “SHAKE” Analarmwillsoundduringthecookingcycl

Seite 22

MANUAL OPERATION1. Press and hold the ON/OFF key for 1 second to energize the fryer. The following will appear in the Alpha/Numeric Display: “MELTC

Seite 23

DELIVERY This Alto-Shaam appliance has been thoroughly tested and inspected to ensure only the highest quality unit is provided. Upon receipt, check

Seite 24

MANUAL OPERATION5. Press the MANUAL TIME key after the correct amount of time has been entered. The fryer basket will automatically lower into t

Seite 25

CONTROL PROGRAMMING OVERVIEWInitial access to the programming mode must start with the control in the OFF position.Entering the “PROGRAM” mode provide

Seite 26 - PANEL IDENTIFICATION

PROGRAMMING THE CONTROLStarting with the control in the OFF position, press and hold the “PROGRAM” key for a period of 5 to 10 seconds.“Boil”willa

Seite 27 - DELUXE CONTROL OPERATION

PROGRAMMING THE CONTROL “SetPoint This program allows the operator to change the temperature of the frypot oil/shortening. The set-pointtemperatur

Seite 28

PROGRAMMING THE CONTROL “Product” The fryer control has been preset at the factory with four product menu items and two programmable spaces in the d

Seite 29

PROGRAMMING THE CONTROL “Product” “Item” Press and hold any one of the twelve product keys to be programmed or modifi ed. The product, as curren

Seite 30

PROGRAMMING THE CONTROL “Product” “TimeMod” This sub-menu allows the operator to compensate for any drop in oil/shortening temperature as it relates

Seite 31

Gas Fryer Operation & Care Manual • 35DELUXE CONTROL OPERATIONPROGRAMMING THE CONTROL “Product” “ShakTime” The “ShakTime” sub-menu provide

Seite 32

Gas Fryer Operation & Care Manual • 36DELUXE CONTROL OPERATIONTo exit the control programming mode at any time, press and hold the LEFT ar

Seite 33

PROGRAMMING THE CONTROL “BsktLift” The Basket Lift program provides the operator with the ability to enable or disable the automatic basket lift func

Seite 34

CAUTIONUsed to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the

Seite 35

PROGRAMMING THE CONTROL“Language” The language option is only available in English “ENG” at this time. “TempDisp” The operator can choose to have th

Seite 36

PROGRAMMING THE CONTROL “FILTER” The filter program is a monitor to notify the operator to service the oil/shortening after a specified number of pro

Seite 37

PROGRAMMING THE CONTROL“FILTER CNT” The filter count program allows the operator to change the number of processed fry loads within a range of 5 to 1

Seite 38

PROGRAMMING THE CONTROL “LO BAND” “LO BAND” provides an alarm notification when the temperature of the oil is lower than the set-point temperature.

Seite 39

Gas Fryer Operation & Care Manual • 42SERVICEDELUXE CONTROL TROUBLESHOOTING1. FRYER WILL NOT POWER-UP A. Make certain cord is plugged

Seite 40

Gas Fryer Operation & Care Manual • 43DELUXE CONTROL OPERATION ERROR CODE DISPLAY MESSAGES pro bable causeAmbient temperature surrounding

Seite 41

Gas Fryer Operation & Care Manual • 44DELUXE CONTROL OPERATIONDELUXE CONTROL TROUBLESHOOTING1. Press and hold the ON/OFF key for 1 second.

Seite 42

Gas Fryer Operation & Care Manual • 45SERVICE DANGERDISCONNECT UNIT FROM POWER SOURCE BEFORE CLEANING OR SERVICING.CAUTIONTHIS SECTION IS

Seite 43

Gas Fryer Operation & Care Manual • 46ASF-75G SERVICE*****BSTFIL/W,NOITARTLIF,EXULED,V021-G57-FSA.A.S.U0540-25035IW,SLLAFEENOMONEMECNARELOT

Seite 44

Gas Fryer Operation & Care Manual • 47ASF-75G SERVICE4151615223222124272191811340119023158101310268219139147422322212815G57LACIRTCELEDNAROT

Seite 45

38-11/16" (983mm)OILTROLLEY50-3/16" (1274mm) LIFT UP44-13/16" (1138mm) LIFT DOWNElectricalGasConnection1/2" NPT24-13/16" (629

Seite 46

Gas Fryer Operation & Care Manual • 48ASF-75G SERVICE423A1.A.S.U0540-25035IW,SLLAFEENOMONEMECNARELOTDRADNATSESIWREHTOSSELNUDEIFICEPS:YB:ELT

Seite 47

Gas Fryer Operation & Care Manual • 49ASF-75G SERVICE411245916702890131118171351261233242625292827291032242A.A.S.U0540-25035IW,SLLAFEENOMON

Seite 48 - ASF-75G SERVICE

Gas Fryer Operation & Care Manual • 50ASF-75G SERVICEA017161612121315861734321194151716161212181.A.S.U0540-25035IW,SLLAFEENOMONEMECNARELOTD

Seite 49

Gas Fryer Operation & Care Manual • 51ASF-75G SERVICE23135008596 LIFT ASSYITEM PART NO DESCRIPTION QTY1 5008597 SINGLELIFTASSEMBLY

Seite 50

Gas Fryer Operation & Care Manual • 52ASF-60G SERVICEASF-60G SERVICE2a & 2b896745See details for these assemblies on following pages:IT

Seite 51

Gas Fryer Operation & Care Manual • 53ASF-60G SERVICE5007518 LIFT ASSEMBLY-ASF-60ITEM PART NO DESCRIPTION QTY 1 5010972 GUIDECOLUM

Seite 52

Gas Fryer Operation & Care Manual • 54ASF-60G SERVICE5008503 LOWER PANEL WITH DRAIN PIPEITEM PART NO DESCRIPTION QTY 1 1009173 PANE

Seite 53

Gas Fryer Operation & Care Manual • 55ASF-60G SERVICE41327METI.ONREBMUNTRAP NOITPIRCSEDYTQ7 01182-EPDRACUNEM-TRESNI266922-UN23-8#XEH,TUN65

Seite 54

Gas Fryer Operation & Care Manual • 56ASF-75G SERVICE

Seite 55 - ASF-60G SERVICE

Gas Fryer Operation & Care Manual • 57ASF-75G SERVICE

Seite 56

ASF-60G SPECIFICATIONSINSTALLATIONGas Fryer Operation & Care Manual • 4DIMENSIONS exterior (h x w x d)44-3/4”x15-3/4”x33-5/8”(1136mmx

Seite 57

Gas Fryer Operation & Care Manual • 58ASF-60G SERVICE

Seite 58

Gas Fryer Operation & Care Manual • 59ASF-60G SERVICE

Seite 59

TRANSPORTATION DAMAGE and CLAIMSAll Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the pr

Seite 60

NOTE: To avoid equipment damage, remove the Mobile Oil Trolley before moving this appliance with a forklift or pallet lift.MINIMUM CLEARANCE REQUIRE

Seite 61

1. It is the responsibility of the installer to verify that this fryer installation is in compliance with the specicationslistedinthismanualand

Seite 62 - LIMITED WARRANTY

VENTILATION1. AsingleASF-75GorASF-60Gauto-liftgasfryerrequires a minimum of 120 CFM make-up air for naturalgasand48CFMforpropanegas.